CSENEXU-200-Voltage Protection

Numerical Voltage Protection Relay (Draw out) : CSENEX-U 200

FEATURES
  • Multi-function Protection for Distribution
  • Voltage protection
  • 50/60Hz Nominal Frequency (Site selectable)
  • Draw-out Relay with Self CT shorting modular design
  • User configurable Digital Input / Digital Output
  • Fault & Event records with date and time stamp
  • IEC-103 / MODBUS communication protocol
  • Interactive HMI with USB Plug & Play support
  • Common configuration Software-CSE LIVELINK

PRO range of relays provide reliable and high-performance protection.

The CSENEX-U 200 is a relay for AC voltage supervision with universal application, it protects the three-phase network against over, under voltage, unbalance or earth faults in isolated networks. Beside the pure RMS value measurement of the line voltage the CSENEX-U 200 can detect the phase sequence, voltage unbalance and earth faults.

The IRU-PRO is a relay for AC Voltage supervision with universal application, it protects the three-phase network against over, under voltage, unbalance or earth faults in isolated networks. Beside the pure RMS value measurement of the line voltage the IRU-PRO evaluates the symmetrical components (U1, U2 & U0 sequence system). By evaluating these components relay IRU-PRO can detect the phase sequence, voltage unbalance and earth faults.

  • CSENEX-U 200 safeguards expensive electrical devices, motors, transformers and appliances from damage caused by voltage fluctuations (overvoltage and undervoltage).
  • Overvoltage can damage insulation and cause equipment burnout, while undervoltage causes motors to draw too much current, resulting in overheating and damage. NEX-U 200 relay instantly disconnects the circuit to prevent these issues.
  • When equipment operates under safe and optimal voltage conditions, CSENEX-U increase the longevity of connected devices, reducing the frequency of costly repairs.
  • Enhanced Safety and Risk Reduction
  • The relay’s automatic and fast tripping action localises the fault and minimises the duration of system disruption.
  • Recording detailed information about fault events (time, duration, voltage waveform).
  • Allowing the system to automatically re-energise after a set time once the voltage returns to normal limits.
  • For three-phase systems, CSENEX-U200 often provide additional benefits like protection against phase loss, phase reversal, and phase imbalance, which are critical for the safe operation of three-phase motors.