{"id":389,"date":"2026-03-30T04:35:10","date_gmt":"2026-03-30T04:35:10","guid":{"rendered":"http:\/\/cselectric.co.in\/blog\/?p=389"},"modified":"2026-04-07T09:22:41","modified_gmt":"2026-04-07T09:22:41","slug":"residual-current-circuit-breaker-rccb","status":"publish","type":"post","link":"https:\/\/cselectric.co.in\/blog\/residual-current-circuit-breaker-rccb\/","title":{"rendered":"RCCBs \u2013 Types, Principle, Limitation and Benefits"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_80 counter-hierarchy ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/cselectric.co.in\/blog\/residual-current-circuit-breaker-rccb\/#Why_RCCB\" >Why RCCB?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/cselectric.co.in\/blog\/residual-current-circuit-breaker-rccb\/#Working_Principle\" >Working Principle<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/cselectric.co.in\/blog\/residual-current-circuit-breaker-rccb\/#Benefits_of_RCCB\" >Benefits of RCCB<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/cselectric.co.in\/blog\/residual-current-circuit-breaker-rccb\/#Sensitivity_of_RCCB\" >Sensitivity of RCCB<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/cselectric.co.in\/blog\/residual-current-circuit-breaker-rccb\/#Limitations_of_RCCB\" >Limitations of RCCB<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/cselectric.co.in\/blog\/residual-current-circuit-breaker-rccb\/#TYPES_OF_RCCB\" >TYPES OF RCCB:<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/cselectric.co.in\/blog\/residual-current-circuit-breaker-rccb\/#Importance_RCCB_in_Power_distribution_board\" >Importance RCCB in Power distribution board:<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/cselectric.co.in\/blog\/residual-current-circuit-breaker-rccb\/#C_S_RCCB\" >C&amp;S RCCB<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/cselectric.co.in\/blog\/residual-current-circuit-breaker-rccb\/#FAQs\" >FAQs<\/a><\/li><\/ul><\/nav><\/div>\n<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_column_text css=&#8221;&#8221;]While electricity has become an indispensable component of our lives, the fact is, it comes with its own hazards to human life and property. Electrocution and fire being the two major risks associated with electricity, one cannot afford to be negligent when it comes to insulating equipment.<br \/>\nA\u202f<a href=\"https:\/\/cselectric.co.in\/products-solutions\/final-distribution-products\/residual-current-circuit-breaker-rccb\/\" target=\"_blank\" rel=\"noopener\">Residual Current Circuit Breaker (RCCB)<\/a>\u202fis an important safety measure when it comes to protection of electrical circuits. It is a current sensing device, which can automatically measure and disconnect the circuit whenever a fault occurs in the connected circuit or the current exceeds the rated sensitivity.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Why_RCCB\"><\/span><strong>Why RCCB?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>RCCBs are designed to detect the leakage current which prevents from the hazards like electric shock. RCCB can detect the small imbalance current and disconnect the circuit quickly to minimise the risk of electric shock &amp; hazards.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Working_Principle\"><\/span><strong>Working Principle<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>RCCBs operate based on Kirchhoff\u2019s Current Law, which states that the sum of currents entering and leaving a circuit must be zero. They continuously monitor the current flowing through the live and neutral. Under normal conditions, the current entering through the live wire equals to the current returning through the neutral wire. If there&#8217;s a difference in incoming and outgoing current it indicates that is leakage of current which is detect by RCCB and rapidly disconnect the circuit within milliseconds to prevent electric shock or fire.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Benefits_of_RCCB\"><\/span><strong>Benefits of RCCB<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li>Safety against Electrical Shocks &amp; Fire hazards<\/li>\n<li>Automatically disconnects the circuit when the rated sensitivity is exceeded<\/li>\n<li>Offers possibility of dual termination both for cable and busbar connections<\/li>\n<li>Offers protection against voltage fluctuation as it includes a filtering device that guards against transient voltage levels.<\/li>\n<li>RCCB can be installed in various industrial, residential &amp; commercial applications.<\/li>\n<li>Early detection of electrical hazards, ensuring a safer environment.<\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"Sensitivity_of_RCCB\"><\/span><strong>Sensitivity of RCCB<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Sensitivity of RCCB can be defined as the amount of leakage current that will trigger the device to trip and disconnect the circuit. For different application there is different sensitivity. Basically there are three sensitivities we prefer 30mA, 100mA, 300mA. In Residential areas generally we use RCCB of sensitivity 30mA. In case of protection from fire due to leakage current we should use RCCB of sensitivity 300mA.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Limitations_of_RCCB\"><\/span><strong>Limitations of RCCB<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>While RCCBs are highly effective, they have certain limitations:<\/p>\n<ul>\n<li>RCCB does not guarantee to operate if non-standard waveforms are generated by loads. It\u2019s mainly because RCCB is designed to operate on normal supply waveforms.<\/li>\n<li>There might be some unwanted tripping of RCCB. It\u2019s mainly because whenever there are sudden changes in electrical load, there can be small current flow to earth especially in the old appliances.<\/li>\n<li>RCCB does not protect against line-neutral shocks. It\u2019s mainly because current in them is balanced. The current gets balanced as both terminals are held together.<\/li>\n<li>RCCBs do not protect against overcurrent (overload) or short-circuit conditions.<\/li>\n<li>RCCBs may trip due to transient currents or voltage surges, leading to nuisance tripping if not properly selected or installed.<\/li>\n<\/ul>\n<p><strong>RCCB can be classified in various types as mentioned below:<\/strong><\/p>\n<ul>\n<li><strong>Type AC:<\/strong> Detects and trips on alternating sinusoidal residual currents.<\/li>\n<li><strong>Type A:<\/strong> Detects both alternating and pulsating direct residual currents.<\/li>\n<li><strong>Type B:<\/strong> Suitable for detecting smooth direct residual currents, often used in industrial applications.<\/li>\n<li><strong>Type F:<\/strong> Designed for applications where both AC and DC residual currents are present, such as in variable speed drives.<\/li>\n<li><strong>Type H:<\/strong> Offers increased sensitivity for enhanced protection in critical environments.<\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"TYPES_OF_RCCB\"><\/span><strong>TYPES OF RCCB:<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>2-Pole RCCB<\/p>\n<ul>\n<li><strong>Application:<\/strong> Used in single-phase supply systems, connecting one live and one neutral wire.<\/li>\n<li><strong>Function:<\/strong> Monitors the current between the live and neutral wires and trips when an imbalance is detected.<\/li>\n<\/ul>\n<p>4-Pole RCCB<\/p>\n<ul>\n<li><strong>Application:<\/strong> Designed for three-phase supply systems, connecting three live wires and one neutral wire.<\/li>\n<li><strong>Function:<\/strong> Monitors the current across all three phases and the neutral, providing comprehensive protection.<\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"Importance_RCCB_in_Power_distribution_board\"><\/span><strong>Importance RCCB in Power distribution board:<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><a href=\"https:\/\/cselectric.co.in\/blog\/residual-current-circuit-breaker-rccb\/\" target=\"_blank\" rel=\"noopener\">RCCBs<\/a>\u202fare connected parallel to the MCBs inside distribution boards. The neutral connection is done to the neutral links &amp; phase is connected in parallel with MCB as the MCB offers protection against overload and short circuit, and RCCB offers the protection against earth leakage. The neutral is required for the RCCB in order to sense the incoming and outgoing current.<\/p>\n<p>A special kind of distribution board called PPI \u2018Per Phase Isolation\u2019 Distribution Board is there in which there is a provision to install RCCB in each phase with separate neutral links provided for each phase such that, the phase which is experiencing a current leakage only that RCCB should trip and other phases can continue to work without any disturbance.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-1640 aligncenter lazyload\" src=\"data:image\/gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==\" data-src=\"https:\/\/cselectric.co.in\/blog\/wp-content\/uploads\/2018\/12\/RCCB-diagram-300x300.png\" alt=\"\" width=\"300\" height=\"300\" data-sizes=\"auto\" data-srcset=\"https:\/\/cselectric.co.in\/blog\/wp-content\/uploads\/2018\/12\/RCCB-diagram-300x300.png 300w, https:\/\/cselectric.co.in\/blog\/wp-content\/uploads\/2018\/12\/RCCB-diagram-150x150.png 150w, https:\/\/cselectric.co.in\/blog\/wp-content\/uploads\/2018\/12\/RCCB-diagram-20x21.png 20w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<h2><span class=\"ez-toc-section\" id=\"C_S_RCCB\"><\/span><strong>C&amp;S RCCB<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>Rating from 10 Amp \u2026.100 Amp<\/strong><br \/>\n<strong>Sensitivity 30,100,300 mA<\/strong><\/p>\n<p>RCCB is therefore extremely important in providing real time protection for circuits. In industries and high voltage commercial set ups especially, its importance cannot be undermined as there is always risk of shocks and accidental deaths on account of it. At C&amp;S Electric, we offer\u202f<a href=\"https:\/\/cselectric.co.in\/products-solutions\/final-distribution-products\/residual-current-circuit-breaker-rccb\/\" target=\"_blank\" rel=\"noopener\">Wintrip RCCB<\/a>, a state-of-the-art product fit for industrial, residential and commercial application. C&amp;S RCCBs conforms to IEC 61008 \u2013 1 and is used for both control and isolation of electrical circuits. Being a respected global brand for power management products for over 50 years, with C&amp;S Electric you can rest assured knowing that you are in safe hands.[\/vc_column_text][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1752069081651{margin-top: 30px !important;}&#8221;][vc_column][vc_column_text css=&#8221;.vc_custom_1752069184640{margin-bottom: 30px !important;}&#8221;]<\/p>\n<h2><span class=\"ez-toc-section\" id=\"FAQs\"><\/span><strong>FAQs<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>[\/vc_column_text][vc_tta_accordion active_section=&#8221;1&#8243; css=&#8221;.vc_custom_1752069132525{margin-top: 30px !important;}&#8221;][vc_tta_section title=&#8221;What is RCCB?&#8221; tab_id=&#8221;1752068585089-fb2c60df-fd13&#8243;][vc_column_text css=&#8221;&#8221;]A Residual Current Circuit Breaker (RCCB) is an electrical protecting device that protect against the leakage current and prevents electric shock and fire hazards in an electrical circuit. RCCB detect the leakage current and fastly trip the circuit by cutting off the power supply. It is easy to install.<\/p>\n<p><strong>Function:<\/strong><br \/>\nIt detects the difference between the live (phase) and neutral currents. If there&#8217;s an imbalance (due to current leakage to earth), it trips the circuit, cutting off the power supply instantly.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;What is the residual current circuit breaker (RCCB) used for?&#8221; tab_id=&#8221;1752068585094-937c4a67-439c&#8221;][vc_column_text css=&#8221;&#8221;]RCCBs are used for:<\/p>\n<ul>\n<li>Protecting human life against electric shocks from direct or indirect contact with live parts.<\/li>\n<li>Preventing electrical fires caused by earth leakage currents.<\/li>\n<li>Domestic, commercial, and industrial application.<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Which RCCB is better, 30mA or 100mA?&#8221; tab_id=&#8221;1752068787796-a73ff8ff-44df&#8221;][vc_column_text css=&#8221;&#8221;]<\/p>\n<ul>\n<li><strong>30mA RCCB:<\/strong><br \/>\nIt is best for personal protection because it trips quickly to protect from electric shock. Mostly used in homes and offices.<\/li>\n<li><strong>100mA RCCB:<\/strong><br \/>\nIt is Less sensitive &amp; suitable for equipment and fire protection. It is used where some level of leakage current is normal.<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Why does RCCB always trip?&#8221; tab_id=&#8221;1752068857498-1d716c0c-e8db&#8221;][vc_column_text css=&#8221;&#8221;]<\/p>\n<ol>\n<li>RCCB trip because of earth leakage due to faulty wiring or insulation.<\/li>\n<li>If there is Moisture in appliances or connections.<\/li>\n<li>Overloaded neutral wires or shared neutrals causing imbalance.<\/li>\n<li>Incorrect RCCB rating.<\/li>\n<\/ol>\n<p>[\/vc_column_text][\/vc_tta_section][\/vc_tta_accordion][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_column_text css=&#8221;&#8221;]While electricity has become an indispensable component of our lives, the fact is, it comes with its own hazards to human life and property. Electrocution and fire being the two major risks associated with electricity, one cannot afford to be negligent when it comes to insulating equipment. A\u202fResidual Current Circuit Breaker (RCCB)\u202fis an important&hellip;<\/p>\n","protected":false},"author":1,"featured_media":1637,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[251],"tags":[],"class_list":["post-389","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.7 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>RCCB&#039;s Principle, Benefits &amp; Limitations - C&amp;S Electric Blog<\/title>\n<meta name=\"description\" content=\"RCCB Stands for Residual Current Circuit Breaker. Here&#039;s a complete guide to knowing the Principles, Benefits &amp; Limitations, etc. Learn more at C&amp;S Electric\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/cselectric.co.in\/blog\/residual-current-circuit-breaker-rccb\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"RCCB&#039;s Principle, Benefits &amp; Limitations - C&amp;S Electric Blog\" \/>\n<meta property=\"og:description\" content=\"RCCB Stands for Residual Current Circuit Breaker. Here&#039;s a complete guide to knowing the Principles, Benefits &amp; Limitations, etc. Learn more at C&amp;S Electric\" \/>\n<meta property=\"og:url\" content=\"https:\/\/cselectric.co.in\/blog\/residual-current-circuit-breaker-rccb\/\" \/>\n<meta property=\"og:site_name\" content=\"C&amp;S Electric Blog\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-30T04:35:10+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-07T09:22:41+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/cselectric.co.in\/blog\/wp-content\/uploads\/2018\/12\/RCCB-Image.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"960\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"C&amp;S Electric\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"RCCB&#039;s Principle, Benefits &amp; Limitations - C&amp;S Electric Blog\" \/>\n<meta name=\"twitter:description\" content=\"RCCB Stands for Residual Current Circuit Breaker. Here&#039;s a complete guide to knowing the Principles, Benefits &amp; Limitations, etc. Learn more at C&amp;S Electric\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"C&amp;S Electric\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"RCCB's Principle, Benefits & Limitations - C&S Electric Blog","description":"RCCB Stands for Residual Current Circuit Breaker. Here's a complete guide to knowing the Principles, Benefits & Limitations, etc. Learn more at C&S Electric","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/cselectric.co.in\/blog\/residual-current-circuit-breaker-rccb\/","og_locale":"en_US","og_type":"article","og_title":"RCCB's Principle, Benefits & Limitations - C&S Electric Blog","og_description":"RCCB Stands for Residual Current Circuit Breaker. Here's a complete guide to knowing the Principles, Benefits & Limitations, etc. Learn more at C&S Electric","og_url":"https:\/\/cselectric.co.in\/blog\/residual-current-circuit-breaker-rccb\/","og_site_name":"C&amp;S Electric Blog","article_published_time":"2026-03-30T04:35:10+00:00","article_modified_time":"2026-04-07T09:22:41+00:00","og_image":[{"width":1920,"height":960,"url":"https:\/\/cselectric.co.in\/blog\/wp-content\/uploads\/2018\/12\/RCCB-Image.png","type":"image\/png"}],"author":"C&amp;S Electric","twitter_card":"summary_large_image","twitter_title":"RCCB's Principle, Benefits & Limitations - C&S Electric Blog","twitter_description":"RCCB Stands for Residual Current Circuit Breaker. Here's a complete guide to knowing the Principles, Benefits & Limitations, etc. Learn more at C&S Electric","twitter_misc":{"Written by":"C&amp;S Electric","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/cselectric.co.in\/blog\/residual-current-circuit-breaker-rccb\/","url":"https:\/\/cselectric.co.in\/blog\/residual-current-circuit-breaker-rccb\/","name":"RCCB's Principle, Benefits & Limitations - C&S Electric Blog","isPartOf":{"@id":"https:\/\/cselectric.co.in\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/cselectric.co.in\/blog\/residual-current-circuit-breaker-rccb\/#primaryimage"},"image":{"@id":"https:\/\/cselectric.co.in\/blog\/residual-current-circuit-breaker-rccb\/#primaryimage"},"thumbnailUrl":"https:\/\/cselectric.co.in\/blog\/wp-content\/uploads\/2018\/12\/RCCB-Image.png","datePublished":"2026-03-30T04:35:10+00:00","dateModified":"2026-04-07T09:22:41+00:00","author":{"@id":"https:\/\/cselectric.co.in\/blog\/#\/schema\/person\/70302397ddce7788addac419935cbefc"},"description":"RCCB Stands for Residual Current Circuit Breaker. Here's a complete guide to knowing the Principles, Benefits & Limitations, etc. Learn more at C&S Electric","breadcrumb":{"@id":"https:\/\/cselectric.co.in\/blog\/residual-current-circuit-breaker-rccb\/#breadcrumb"},"inLanguage":"en","potentialAction":[{"@type":"ReadAction","target":["https:\/\/cselectric.co.in\/blog\/residual-current-circuit-breaker-rccb\/"]}]},{"@type":"ImageObject","inLanguage":"en","@id":"https:\/\/cselectric.co.in\/blog\/residual-current-circuit-breaker-rccb\/#primaryimage","url":"https:\/\/cselectric.co.in\/blog\/wp-content\/uploads\/2018\/12\/RCCB-Image.png","contentUrl":"https:\/\/cselectric.co.in\/blog\/wp-content\/uploads\/2018\/12\/RCCB-Image.png","width":1920,"height":960},{"@type":"BreadcrumbList","@id":"https:\/\/cselectric.co.in\/blog\/residual-current-circuit-breaker-rccb\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"C&amp;S","item":"https:\/\/cselectric.co.in\/blog\/"},{"@type":"ListItem","position":2,"name":"Knowledge","item":"https:\/\/cselectric.co.in\/blog\/category\/knowledge\/"},{"@type":"ListItem","position":3,"name":"RCCBs \u2013 Types, Principle, Limitation and Benefits"}]},{"@type":"WebSite","@id":"https:\/\/cselectric.co.in\/blog\/#website","url":"https:\/\/cselectric.co.in\/blog\/","name":"C&amp;S Electric Blog","description":"Power Management","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/cselectric.co.in\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en"}]}},"_links":{"self":[{"href":"https:\/\/cselectric.co.in\/blog\/wp-json\/wp\/v2\/posts\/389","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cselectric.co.in\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cselectric.co.in\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cselectric.co.in\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/cselectric.co.in\/blog\/wp-json\/wp\/v2\/comments?post=389"}],"version-history":[{"count":39,"href":"https:\/\/cselectric.co.in\/blog\/wp-json\/wp\/v2\/posts\/389\/revisions"}],"predecessor-version":[{"id":1831,"href":"https:\/\/cselectric.co.in\/blog\/wp-json\/wp\/v2\/posts\/389\/revisions\/1831"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cselectric.co.in\/blog\/wp-json\/wp\/v2\/media\/1637"}],"wp:attachment":[{"href":"https:\/\/cselectric.co.in\/blog\/wp-json\/wp\/v2\/media?parent=389"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cselectric.co.in\/blog\/wp-json\/wp\/v2\/categories?post=389"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cselectric.co.in\/blog\/wp-json\/wp\/v2\/tags?post=389"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}